InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > SIMSEN Version : 3.5.0 (Jul, 2023)
InHydro Element Specific > Release Mode : Normal
InHydro Element Specific > PID              : 3524
InHydro Element Specific > SIMSEN LOG  FILE : Date : 17/04/2025 Time : 11:06:06
InHydro Element Specific > INPUT  MAIN FILE : veytx_ph_420_70.DAT
InHydro Element Specific > OUTPUT MAIN FILE : veytx_ph_420_70.TXT
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > Loading Parameters of ROOT model : veytx_ph_420_70 (Depth level : 0)
InHydro Element Specific > ...........................................................................
InHydro Element Specific > Parsing Section 'COMMENT'
InHydro Element Specific > ...........................................................................
InHydro Element Specific > ...........................................................................
InHydro Element Specific > Parsing Section 'SIMULATION PARAMETERS'
InHydro Element Specific > ...........................................................................
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > SIMULATION PARAMETERS : Time min                         [sec] =  0.000E+00
InHydro Element Specific > SIMULATION PARAMETERS : Time max                         [sec] =  1.200E+03
InHydro Element Specific > HLF PARAMETERS :        Integration step                 [sec] =  1.000E-02
InHydro Element Specific > SIMULATION PARAMETERS : Precision for immediate events     [%] =  1.000E+00
InHydro Element Specific > SIMULATION PARAMETERS : Precision for simultaneous events  [%] =  1.000E+00
InHydro Element Specific > SIMULATION PARAMETERS : Integration process                [-] =  RK45
InHydro Element Specific > SIMULATION PARAMETERS : Write in output files every        [1] =  10
InHydro Element Specific > SIMULATION PARAMETERS : Initial conditions from        [E/M/C] =  ELEMENTS
InHydro Element Specific > SIMULATION PARAMETERS : Disturbances activated           [Y/N] =  YES
InHydro Element Specific > ...........................................................................
InHydro Element Specific > Parsing Section 'CONSTANT DATA'
InHydro Element Specific > ...........................................................................
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > CONSTANT DATA : pi                        =  3.142E+00
InHydro Element Specific > CONSTANT DATA : Step                      =  1.000E-02
InHydro Element Specific > CONSTANT DATA : inf                       =  1.000E+09
InHydro Element Specific > CONSTANT DATA : TAU                       =  5.000E+02
InHydro Element Specific > CONSTANT DATA : Ao                        =  1.000E+01
InHydro Element Specific > ...........................................................................
InHydro Element Specific > Parsing Section 'PARAMETERS'
InHydro Element Specific > ...........................................................................
InHydro Element Specific > ...........................................................................
InHydro Element Specific > Parsing Section 'ELEMENTS AND RELATED FILES'
InHydro Element Specific > ...........................................................................
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ELEMENT : Systeme Element : SysEle=  @SYSTEM
InHydro Element Specific > ELEMENT : Valve            =  VALVE1
InHydro Element Specific > ELEMENT : Surge Tank       =  STANK1
InHydro Element Specific > ELEMENT.PARAMETER :           STANK1.AO   =  1.000E+01
InHydro Element Specific > ELEMENT : Valve            =  VALVE_S
InHydro Element Specific > ELEMENT : Pipe Z elements  =  PIPE2
InHydro Element Specific >   dt min = dx/a =  0.0500000
InHydro Element Specific > ELEMENT : Reservoir        =  RESERV2
InHydro Element Specific > ELEMENT : Pump             =  PUMP
InHydro Element Specific > ELEMENT : Reservoir        =  RESERV1
InHydro Element Specific > ELEMENT : Pipe Z elements  =  PIPE1
InHydro Element Specific >   dt min = dx/a =  0.1085385
InHydro Element Specific > ELEMENT : Pipe Z elements  =  PIPE0
InHydro Element Specific >   dt min = dx/a =  0.3384615
InHydro Element Specific > ELEMENT : Number of elements =  10
InHydro Element Specific > ...........................................................................
InHydro Element Specific > Parsing Section 'INITIAL CONDITIONS'
InHydro Element Specific > ...........................................................................
InHydro Element Specific > ...........................................................................
InHydro Element Specific > Parsing Section 'DISTURBANCES'
InHydro Element Specific > ...........................................................................
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ***************************************************************************
InHydro Element Specific > Warning 1 in MAIN FILE : DISTURBANCES : MEPUMP : name not defined !
InHydro Element Specific > ***************************************************************************
InHydro Element Specific > ***************************************************************************
InHydro Element Specific > Warning 1 in MAIN FILE : DISTURBANCES : MEPUMP : name not defined !
InHydro Element Specific > ***************************************************************************
InHydro Element Specific > ***************************************************************************
InHydro Element Specific > Warning 1 in MAIN FILE : DISTURBANCES : MEPUMP : name not defined !
InHydro Element Specific > ***************************************************************************
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > Building and initializing global ODE system
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > Initial resolution in progress...
InHydro Element Specific > Initial resolution done with dimension 93 !
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > Creating results files (.vis)
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > Preparing system for simulation start (initialization of derivatives)
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > ---------------------------------------------------------------------------
InHydro Element Specific > Simulation performed in 0 h : 0 min : 34 sec